Home›Repair guides›Westerbeke›Starting Procedure

Westerbeke 90A FOUR — Starting Procedure

Operation · Engine

For the Westerbeke 90A FOUR, from the Westerbeke operator's manual.

Before you start

  • Never run the starter for more than 30 seconds.
  • Prolonged cranking without the engine starting can result in the engine exhaust system filling with raw water.

Procedure

  1. Place the transmission in neutral and advance the throttle control to slightly open.
  2. Turn the KEY SWITCH to the ON position (2 o'clock).
  3. Depress the PREHEAT switch per the temperature/preheat chart (approx. 10-20 seconds).
  4. While still depressing PREHEAT, depress START to engage the starter solenoid.
  5. Release START when the engine starts; hold PREHEAT until oil pressure reaches 15 psi.
  6. If the engine does not start in 10 to 20 seconds, release both buttons, wait 30 seconds, repeat and preheat longer.
  7. Check the instruments for proper oil pressure and battery charging voltage.

Specs & values

  • Preheat: 41°F (5°C) or higher approx. 10 seconds
  • Preheat: 41°F (5°C) to 23°F (-5°C) approx. 15 seconds
  • Preheat: 23°F (-5°C) or lower approx. 20 seconds
  • Limit of continuous use 30 seconds before cranking

Source: Westerbeke operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.