SBL/SCL — Plunger Removal and Rectifier Replacement
For the SBL/SCL.
Procedure
- Use 1/4 inch open-end wrench on plunger flats.
- Turn plunger counterclockwise to remove from swing bolt.
- Install new rectifier.
- Connect rectifier AC connections to wiring harness.
- If replacing plunger, install new plunger on swing bolt to same length as removed.
Tools required
- 1/4 inch open-end wrench
Source: manual:mp5668.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.