HomeRepair guidesPlunger Removal and Rectifier/Solenoid Replacement

SBL/SCL — Plunger Removal and Rectifier/Solenoid Replacement

For the SBL/SCL.

Procedure

  1. Use 1/4 inch open-end wrench on the plunger flats.
  2. Turn the plunger counterclockwise to remove the plunger from the swing bolt.
  3. Install the new rectifier.
  4. Connect the rectifier AC connections to the wiring harness.
  5. If replacing the plunger, install the new plunger on the swing bolt.
  6. Assemble plunger to the same length as the one removed.

Tools required

  • 1/4 inch open-end wrench

Source: manual:mp5668.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.