Procedure
- 1) Loosen the cylinder head bolts and remove them.
- 2) Pull the cylinder head up vertically to take it down. If the cylinder head gasket is attached
- on the removed cylinder head, remove it and place it back on engine block. Put the
- removed cylinder head on cardboard to prevent damage to the upper surface of the
- combustion chamber and other sealing surfaces. If more than one cylinder head needs to
- be disassembled, mark the cylinder number on the head for reference.
- 3) Remove the cylinder head gasket. If more than one cylinder head gasket needs to be
- disassembled, mark the cylinder number on the gaskets for reference.
- 4) Remove the intake and exhaust valve module. Refer to disassembly of valve mechanism
- (9.6) for details.
- 5) Remove the valve seal. Valve seals can’t be reused.
Source: manual:4.5L-Engine-Service-Manual-7610033-2.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.