PSI/Doosan — Operating & Maintenance Manual
For these PSI/Doosan models: C185, C185WKUB-T2 Export (E04).
Browse PSI/Doosan generators & specs →
Procedure
- 1.
- Compressor Discharge Pressure Gauge - Indicates pressure in receiver tank, psi
- (kPa).
- 2.
- Hourmeter - Records running time for maintenance.
- 3.
- Service Air Button - After warm-up, PUSH. Provides full air pressure at the service
- outlet.
- 4.
- Power Switch - Rotate to “ON” position to activate system prior to Starting. Rotate
- “OFF” to stop engine.
- Before Starting
- • Open service valve(s) to ensure pressure is relieved in receiver-separator system. Close
- valve(s) in order to build up full air pressure and ensure proper oil circulation.
- • Check battery for proper connections and condition.
- • Check battery for proper connections and condition.
- • Check engine coolant level.
- OPERATION
- Operating & Maintenance Manual
- Book: 46555713 (1-28-2011) Rev B
- 31
- •
- WARNING
- !
- Do not remove pressure cap from a HOT radiator. Allow radiator to cool down
- before removing pressure cap. Use extreme care when removing a pressure cap
- from a liquid cooling system for the engine. The sudden release of pressure from
- a heated cooling system can result in a loss of coolant and possible severe
- personal injury.
- • Check the engine oil level. Maintain per marks on dipstick.
- • Check the fuel level. Add only CLEAN low or ultra low sulfur diesel fuel for maximum
- service from the engine.
- • Check the compressor lubricating fluid level between bottom and midway of the sight glass
- on the separator tank.
- WARNING
- !
- This machine produces loud noise with doors open. Extended exposure to loud
- noise can cause hearing loss. Wear hearing protection when doors or valve (s) are
- open.
- • Close all doors to maintain a cooling air path and to avoid recirculation of hot air. This will
- maximize the life of the engine and compressor and protect the hearing of surrounding
- personnel.
- • Be sure no one is IN or ON the compressor unit.
- WARNING
- !
- Unrestricted air flow from a hose will result in a whipping motion of the hose which
- can cause severe injury or death. A safety device must be attached to the hose at
- the source of supply to reduce pressure in case of hose failure or other sudden
- pressure release. Reference: OSHA regulation 29 CFR Section 1926.302 (b).
- Starting
- • Turn the POWER switch to “ON”.
- • Turn Power switch to “START” position to crank engine. Hold switch in “START”
- position for approximately 5 seconds after engine starts.
- Operating & Maintenance Manual
- OPERATION
- 32
- Book: 46555713 (1-28-2011) Rev B
- NOTICE
- Do not operate the starter motor for more than 30 seconds without allowing at
- least 30 seconds cooling time between start attempts.
- Release Power Switch (it will automatically move to the “ON” position) when the engine starts
- and sustains running.
- • Allow engine to warm up 5 to 10 minutes.
- • If so equipped, press the “Service Air Button”. Open air service valve(s).
- Cold Weather Starting
- • Turn power switch to the glow plug position and hold 10 seconds. Then turn to start.
- NOTICE
- Exercise extreme caution when using a booster battery to start. To jump start:
- Connect the ends of one booster cable to the positive (+) terminals of each
- battery. Then connect one end of the other cable to the negative (-) terminal of
- the booster
Source: manual:46555713 C185WKUB-T2 (E04) OPS 1-28-2011.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.