Power Solutions International — Replace fuel filter

Maintenance

From a Power Solutions International service manual — check it applies to your exact model before use.

Browse Power Solutions International generators & specs →

Before you start

  • Never use an open flame to check for propane leaks

Procedure

  1. Move equipment to well ventilated area and ensure no external ignition sources
  2. On propane units start engine and close manual valve on cylinder, run until engine runs out of fuel
  3. Remove and replace fuel filter
  4. Leak check connections with soapy solution or electronic leak detector
  5. On gasoline fuel pumps with integrated fuel filters or screens follow OEM procedures
  6. On externally mounted filters close manual valve at gasoline tank to prevent fuel drain
  7. Drain excess fuel into approved container and replace filter
  8. Start engine and leak check all connections

Source: Power Solutions International service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.