Power Solutions International 560001-R2 — Replacing the Fuel Filter
Maintenance · In-line fuel filter
For the Power Solutions International 560001-R2, from the Power Solutions International service manual.
Browse Power Solutions International generators & specs →
Before you start
- A small amount of fuel may still be present in the fuel line; use gloves and eye protection.
- Ensure manual valve is fully closed if liquid fuel continues to flow.
Procedure
- Move equipment to a well ventilated area; verify no sparks, ignition or heat sources.
- Start the engine.
- If positive pressure fuel system, run engine with fuel supply closed to remove fuel from system.
- Slowly loosen inlet fitting and disconnect.
- Slowly loosen outlet fitting and disconnect.
- Remove filter housing from the equipment.
- Check for contamination; tap opening of filter on a clean cloth; check for debris.
- Check canister for proper mounting direction.
- Reinstall filter housing to the equipment.
- Tighten inlet and outlet fittings to specification.
- Leak check inlet/outlet fittings and housing end connection with soapy solution or electronic leak detector.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Power Solutions International service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.