Before you start

  • A small amount of fuel may still be present in the fuel line; use gloves and eye protection.
  • Ensure manual valve is fully closed if liquid fuel continues to flow.

Procedure

  1. Move equipment to a well ventilated area; verify no sparks, ignition or heat sources.
  2. Start the engine.
  3. If positive pressure fuel system, run engine with fuel supply closed to remove fuel from system.
  4. Slowly loosen inlet fitting and disconnect.
  5. Slowly loosen outlet fitting and disconnect.
  6. Remove filter housing from the equipment.
  7. Check for contamination; tap opening of filter on a clean cloth; check for debris.
  8. Check canister for proper mounting direction.
  9. Reinstall filter housing to the equipment.
  10. Tighten inlet and outlet fittings to specification.
  11. Leak check inlet/outlet fittings and housing end connection with soapy solution or electronic leak detector.