Perkins — To Replace Vacuum Fan Impeller

Repair & overhaul

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • Raised hopper may fall. Engage hopper support bar
  • Use blue loctite 242 on shaft threads

Procedure

  1. Dump the machine debris hopper and set the parking brake.
  2. Raise the hopper, engage the prop arm, and lower the hopper.
  3. Shut off the engine; open engine cover and side door.
  4. Remove the vacuum hose and bracket from the front of the vacuum fan housing.
  5. Disconnect the wires to the Thermo Sentry.
  6. Disconnect and plug the three hydraulic hoses at the vacuum fan motor.
  7. Remove two M10 hex screws, washers and rubber isolators holding fan housing to the frame.
  8. Remove solenoid valve mounting bracket and isolator from top of housing.
  9. Tip the vacuum fan assembly forward and remove it from the machine.
  10. Remove the six 0.31 in hex screws holding the front housing to the rear housing.
  11. Remove the crown nut from the impeller shaft; slide the impeller off (save key and shims).
  12. Turn housing over; reinstall shims, key, impeller, and crown nut; tighten crown nut to 34--47 Nm.
  13. Reinstall front housing; tighten 0.31 in hex screws to 22--27 Nm.
  14. Reinstall assembly and hoses; reconnect electrical harness to the Thermo Sentry.

Specs & values

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.