Home›Repair guides›Perkins›TO PRIME FUEL SYSTEM (early machines)

Perkins — TO PRIME FUEL SYSTEM (early machines)

Maintenance

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • Before leaving or servicing machine, stop on level surface and set parking brake

Procedure

  1. Stop the engine and set the machine parking brake.
  2. Fill the fuel tank.
  3. Open the side and top engine access doors.
  4. Open the air vent on top of the fuel filter mounted on engine.
  5. Start engine and run one minute; or crank starter in ten-second intervals until steady fuel flows from vent.
  6. Close the air vent.
  7. Close the access doors.

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.