Home›Repair guides›Perkins›To Drain Hydraulic Fluid Reservoir And Replace Filter Element

Perkins — To Drain Hydraulic Fluid Reservoir And Replace Filter Element

Maintenance

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • Before leaving or servicing machine, stop on level surface and set parking brake

Procedure

  1. Stop the engine and set the parking brake.
  2. Wait for the hydraulic fluid to cool down.
  3. Un-thread and discard the hydraulic fluid filter element; fluid drains through the filter head.
  4. Discard the used hydraulic fluid; loosen the breather-filter cap.
  5. Apply a thin coat of hydraulic fluid to the seal of the new filter element.
  6. Thread and hand tighten the new filter element on the filter head.

Specs & values

  • Replace filter element every 800 hours

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.