Perkins — Starting the Engine
Operation
From a Perkins owner's manual covering: 402D-05, 403D-07, 403D-11, 403D-15, 404D-22, 404D-22T, 404D-22TA. Check it applies to your exact model before use.
Applies to: Perkins 402D-05, Perkins 403D-07, Perkins 403D-11, Perkins 403D-15, Perkins 404D-22, Perkins 404D-22T, Perkins 404D-22TA
Before you start
- Do not use aerosol starting aids such as ether
Procedure
- Move throttle lever to low idle position.
- Turn engine start switch to HEAT position for 6 seconds until glow plug indicator illuminates.
- While glow plug indicator is illuminated, turn switch to START and crank engine.
- When engine starts, release switch.
- Slowly move throttle lever to low idle and allow engine to idle.
- If engine does not start, release switch and allow starter to cool. Repeat steps 2-5.
- Turn start switch to OFF to stop engine.
Specs & values
- Do not operate glow plugs more than 60 seconds at one time
- Do not crank engine more than 30 seconds
Full service-parts list: Perkins 402D-05 →, Perkins 403D-07 →, Perkins 403D-11 →, Perkins 403D-15 →, Perkins 404D-22 →, Perkins 404D-22T →, Perkins 404D-22TA →
Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.