Perkins — Remove Engine from Storage
Maintenance
From a Perkins operator's manual — check it applies to your exact model before use.
Browse Perkins generators & specs →
Procedure
- Remove all outside protective covers.
- Change the oil and filters.
- Check the condition of the fan and alternator belts; replace the belts if necessary.
- Replace the fuel filter elements.
- Remove the plastic covers from the air cleaner elements.
- Use a bar or turning tool to turn the engine in the normal direction of rotation.
- Remove the valve cover; put a large amount of engine oil on the camshaft, cam followers and valve mechanism.
- If stored more than 1 year, pre-lubricate the oil system at minimum 0.25 bar (3.6 psi) for 15 seconds.
- Remove the plug and connect to the engine oil system (9/16" x 18 tpi); after lubricating, install plug and tighten to 30 N·m (265 lb in).
- Check the condition of all rubber hoses; replace worn or damaged hoses.
- Test the cooling system for a 3 percent to 6 percent concentration of coolant conditioner.
- Prime the engine with clean diesel fuel before starting.
- Ensure that the cooling system is clean, full and has the correct amount of supplemental coolant additive.
- On the first day of operation, check the entire engine several times for leaks and correct operation.
Specs & values
- 0.25 bar (3.6 psi) for 15 seconds
- 30 N·m (265 lb in)
- Connection 9/16" x 18 tpi
- Minimum ambient temperature 10° C (50° F)
Source: Perkins operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.