Home›Repair guides›Perkins›Remove Engine from Storage

Perkins — Remove Engine from Storage

Maintenance

From a Perkins operator's manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Procedure

  1. Remove all outside protective covers.
  2. Change the oil and filters.
  3. Check the condition of the fan and alternator belts; replace the belts if necessary.
  4. Replace the fuel filter elements.
  5. Remove the plastic covers from the air cleaner elements.
  6. Use a bar or turning tool to turn the engine in the normal direction of rotation.
  7. Remove the valve cover; put a large amount of engine oil on the camshaft, cam followers and valve mechanism.
  8. If stored more than 1 year, pre-lubricate the oil system at minimum 0.25 bar (3.6 psi) for 15 seconds.
  9. Remove the plug and connect to the engine oil system (9/16" x 18 tpi); after lubricating, install plug and tighten to 30 N·m (265 lb in).
  10. Check the condition of all rubber hoses; replace worn or damaged hoses.
  11. Test the cooling system for a 3 percent to 6 percent concentration of coolant conditioner.
  12. Prime the engine with clean diesel fuel before starting.
  13. Ensure that the cooling system is clean, full and has the correct amount of supplemental coolant additive.
  14. On the first day of operation, check the entire engine several times for leaks and correct operation.

Specs & values

  • 0.25 bar (3.6 psi) for 15 seconds
  • 30 N·m (265 lb in)
  • Connection 9/16" x 18 tpi
  • Minimum ambient temperature 10° C (50° F)

Source: Perkins operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.