Home›Repair guides›Perkins›Normal engine start

Perkins — Normal engine start

Operation

From a Perkins owner's manual covering: 4000 Series, 4006-23 TAG1A, 4006-23 TAG2A, 4006-23 TAG3A. Check it applies to your exact model before use.

Applies to: Perkins 4006-23 TAG1A, Perkins 4006-23 TAG2A, Perkins 4006-23 TAG3A

Before you start

  • Do not start the engine under load.
  • The air shut off valves must be in the open position (A2) to start the engine.

Procedure

  1. Ensure that the engine load is disengaged.
  2. Check that the shut-off valves are in the open position (A2).
  3. Turn the start key to the position (C3) to engage the starter motor.
  4. If the engine does not start after 10 seconds, allow the start key to return to the 2 position for 20 seconds, then engage the starter motor again.
  5. After the engine has started, check the oil pressure gauge.

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.