Perkins — How to Calibrate the Boom Angle Sensor

Adjustments

From a Perkins service manual covering: 404F-22, 5046D, 5606A, 804D-33, S8015-12264, S8016H-13642, S80X15-12264, S80X16H-13642, S8515-12264, S8516H-13642. Check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • Manually reduce the boom speed as it reaches the fully elevated position.

Procedure

  1. Pull out the red Emergency Stop button at the ground controls.
  2. Turn the key switch to platform controls.
  3. Move and hold the drive enable toggle switch right and pull out the red Emergency Stop button.
  4. When the alarm sounds, release the drive enable toggle switch.
  5. Momentarily activate the drive enable toggle switch right 12 times to enter Angle Sensor calibration mode.
  6. Start the engine and press down the foot switch.
  7. Momentarily activate the drive enable toggle switch right once to set the stowed position.
  8. Raise the primary boom to fully elevated and momentarily activate the drive enable toggle right once to set the elevated position.

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.