Home›Repair guides›Perkins›How to Adjust the Joystick Max-out Setting

Perkins — How to Adjust the Joystick Max-out Setting

Adjustments · Platform Controls joystick

From a Perkins service manual covering: 404F-22, 5046D, 5606A, 804D-33, S8015-12264, S8016H-13642, S80X15-12264, S80X16H-13642, S8515-12264, S8516H-13642. Check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • Do not operate any machine function during the 10 second waiting time.

Procedure

  1. Pull out the red Emergency Stop button at both controls; turn key switch to platform controls. Do not start the engine.
  2. Push in the platform red Emergency Stop button to off.
  3. Move and hold the drive enable toggle switch right and pull out the red Emergency Stop button.
  4. When the alarm sounds, release the drive enable toggle switch.
  5. Momentarily activate the drive enable toggle switch right 4 times to enter max-out calibration mode.
  6. Start the engine from platform controls and press down the foot switch.
  7. Time a full function cycle and adjust max-out with the drive enable toggle to match function times (2% increments, 60% to 120%).
  8. Return joystick to neutral and wait approximately 10 seconds for settings to save.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Boom up 89 to 93 seconds
  • Boom down 90 to 94 seconds
  • Boom extend 73 to 79 seconds
  • Boom retract 79 to 84 seconds

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.