Home›Repair guides›Perkins›Glow Plugs - Remove and Install

Perkins — Glow Plugs - Remove and Install

Maintenance

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • Disconnect battery before working on glow plugs.

Procedure

  1. Turn battery disconnect switch to OFF.
  2. If necessary, remove exhaust gas recirculation valve.
  3. Disconnect wiring harness from glow plugs.
  4. Clean area around glow plugs.
  5. Use a deep socket to remove glow plugs from cylinder head.
  6. Before installing, ensure glow plugs operate correctly.
  7. Ensure threads of glow plugs are clean and free from damage.
  8. Install glow plugs into cylinder head; tighten to 9 N·m.
  9. Connect wiring harness to glow plugs.
  10. Turn battery disconnect switch to ON.
  11. If necessary, install exhaust gas recirculation valve.
  12. Install combined inlet manifold temperature and pressure sensor.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 9 N·m

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.