Home›Repair guides›Perkins›Fuel Transfer Pump - Install

Perkins — Fuel Transfer Pump - Install

Repair & overhaul

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Procedure

  1. Ensure the fuel transfer pump is clean and free from damage.
  2. Lubricate a new O-ring seal with clean engine oil and install to fuel transfer pump (4).
  3. Position fuel transfer pump (4) on pump drive (5). Ensure splines on pump shaft engage correctly in pump drive.
  4. Install bolts (3). Tighten to 55 N·m (41 lb ft).
  5. Remove caps from hose assemblies and connect hose assemblies (1) and (2) to fuel transfer pump (4).
  6. Turn the fuel supply to the "ON" position.
  7. Remove the air from the fuel system.

Specs & values

  • 55 N·m (41 lb ft) bolts (3)

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →