  1. Remove the fuel injection pump
  2. Fit the adaptor 21825513 to the drive shaft of the fuel pump
  3. Fasten it with the nut of the fuel pump gear
  4. Release the screw (B3), set the timing tool to the correct angle
  5. Tighten the screw
  6. Fit the timing tool to the splined adaptor on the fuel pump drive
  7. Release the screw (B1), slide the pointer (B2) forward until it is over the centre of the fuel pump flange
  8. Tighten the screw