Perkins — Fuel Injection Lines Removal
A Perkins service procedure — check it applies to your exact model before use.
Browse Perkins generators & specs →
Before you start
- Contact with high pressure fuel may cause fluid penetration and burn hazards
- High pressure fuel spray may cause a fire hazard
- Care must be taken to ensure fluids are contained during disassembly
Procedure
- Turn the fuel supply to the OFF position
- Turn the battery disconnect switch to the OFF position
- If necessary, remove the Diesel Particulate Filter
- Put identification marks on all hoses and tube assemblies
- Plug all hose assemblies and tube assemblies
Tools required
- Capping Kit
- LASER 4920 1/2 Inch Drive HP Fuel Line Socket Set
Source: manual:Disassembly and Assembly-SM-PERKINS 850 SERIES 854E-E34TA AND 854F-E34T.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.