Home›Repair guides›Perkins›Fuel Filter Base - Remove (Option 2)

Perkins — Fuel Filter Base - Remove (Option 2)

Repair & overhaul

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Before you start

  • NOTICE: Keep all parts clean from contaminants.

Procedure

  1. Turn fuel supply to OFF.
  2. Place container below fuel filter base.
  3. Cut cable strap (4). Disconnect fuel pressure sensor (5) from engine harness.
  4. Disconnect tube assembly (3) and hose assembly (6).
  5. Remove secondary fuel filter (8) and O-ring seal.
  6. Remove bolts (1) and washers (2); remove fuel filter base (7).
  7. If necessary, remove bracket (12): remove bolts (9) and washers (13).

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →