Perkins — High pressure fuel line or lines are removed.
A Perkins service procedure — check it applies to your exact model before use.
Browse Perkins generators & specs →
Procedure
- Outer coverings are chafed or cut.
- Wires are exposed.
- Outer coverings are ballooning.
- Flexible part of the hoses are kinked.
- Outer covers have embedded armoring.
- End fittings are displaced.
- el spray may cause a fire hazard. Failure to fol- low these inspection, maintenance and service in- structions may cause personal injury or death.
- The high-pressure fuel lines are constantly charged with high pressure.
- The internal pressures of the high-pressure fuel lines are higher than other types of fuel system.
- The high-pressure fuel lines are formed to shape and then strengthened by a special process.
- Inspect the high-pressure fuel lines for damage, deformation, a nick, a cut, a crease, or a dent.
- Do not operate the engine with a fuel leak. If there is a leak, do not tighten the connection in order to stop the leak. The connection must only be tightened to the recommended torque. Refer to
- Remove and Fuel injection lines - Install”.
- If the high-pressure fuel lines are torqued correctly, and the high-pressure fuel lines are leaking the high-pressure fuel lines must be replaced.
Source: manual:992774__24_1204e_e44t__4tta_mk_ml.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.