Procedure

  1. 1. Ensure that the No. 1 cylinder is at top dead
  2. center on the compression stroke. Refer to the
  3. Testing and Adjusting Manual, “Finding Top
  4. Center Position for No. 1 Piston”.
  5. g00996409
  6. Illustration 14
  7. Note: Put identification marks on all fuel hose
  8. assemblies and on all tube assemblies for
  9. installation purposes. After being disconnected,
  10. plug all fuel hose assemblies and plug all tube
  11. assemblies with suitable plastic plugs. Also install
  12. dust caps on all of the connectors on the fuel
  13. injection pump. This helps prevent fluid loss, and
  14. this helps to keep contaminants from entering the
  15. system.

Source: manual:Perkins-1103-1104-Series-Workshop-Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.