HomeRepair guidesProcedure 2

Perkins — Procedure 2

A Perkins service procedure — check it applies to your exact model before use.

Browse Perkins generators & specs →

Procedure

  1. 1. Disconnect the fuel injection lines (1) at the fuel
  2. injectors (2).
  3. 2. Disconnect the fuel injection lines (1) at the fuel
  4. injection pump (3).
  5. 3. If it is necessary remove the clamps for the fuel
  6. injection lines or loosen the clamps for the fuel
  7. injection lines. Remove the fuel injection lines (1).
  8. 4. Install dust caps onto the ports of the fuel
  9. injectors and onto the ports of the fuel injection
  10. pump. Install dust caps onto both ends of the
  11. fuel injection lines.
  12. i01939857
  13. Fuel Injection Lines - Install
  14. Installation Procedure