Procedure
- 1. Thoroughly clean the inside of the filter case (2)
- and thoroughly clean the lower face of the filter
- head (5).
- 2. Inspect the thread of a new filter element (4) in
- order to ensure that the thread is not damaged.
- Inspect the thread of the adapter in the filter
- head (5) in order to ensure that the thread is not
- damaged.
- 3. Inspect the condition of the spring and ensure
- that the spring is correctly located within the
- filter case (2).
- 4. Install the new filter element (4) into the filter
- case (2). Push the filter element against the
- spring pressure and rotate the filter element in
- a clockwise direction in order to secure the filter
Tools required