Perkins — NOTICE
A Perkins service procedure — check it applies to your exact model before use.
Browse Perkins generators & specs →
Before you start
- Note: Do not pry the fuel injection pump gear (9)
- Note: Put identification marks on all fuel hose
Procedure
- 1. Ensure that the No. 1 cylinder is at top dead
- center on the compression stroke. Refer to the
- Testing and Adjusting Manual, “Finding Top
- Center Position for No. 1 Piston”.
- g00956204
- Illustration 11
- Typical example
- 2. Loosen the locking screw (5). Rotate the spacer
- (6) in order to allow the locking screw (5) to
- tighten against the shaft of the fuel injection
- pump. Rotate the fuel injection pump gear in a
- counterclockwise direction in order to remove
- the backlash. Tighten the locking screw (5) to a
- torque of 17 N·m (13 lb ft).
- Note: The locking screw (5) must be tightened in
- order to prevent the shaft of the fuel injection pump
- from rotating. The shaft of the fuel injection pump
- must not be rotated after the fuel injection pump
- has been removed from the engine.
- Note: Put identification marks on all fuel hose
Tools required
- 7. Use a suitable puller in order to remove the fuel
Specs & torque values
- 17 N·m
Source: manual:Perkins-1103-1104-Series-Workshop-Manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.