Perkins — Electric Starting Motor - Remove and Install
Repair & overhaul
From a Perkins service manual covering: 402D-05, 403D-07, 403D-11, 403D-15, 404D-22, 404D-22T, KENR6226-10. Check it applies to your exact model before use.
Applies to: Perkins 402D-05, Perkins 403D-07, Perkins 403D-11, Perkins 403D-15, Perkins 404D-22, Perkins 404D-22T
Before you start
- Accidental engine starting can cause injury or death. Place Do Not Operate tag.
Procedure
- Disconnect battery negative cable.
- Mark harness connections.
- Disconnect harness assemblies from starting motor.
- Remove fasteners and starting motor.
- Install starting motor in position.
- Install fasteners and tighten to 50 N·m.
- Connect harness assemblies.
- Connect battery.
Specs & values
- Starting motor fasteners: 50 N·m
Full service-parts list: Perkins 402D-05 →, Perkins 403D-07 →, Perkins 403D-11 →, Perkins 403D-15 →, Perkins 404D-22 →, Perkins 404D-22T →