Perkins — Crankcase Breather Element Cleaning
A Perkins service procedure — check it applies to your exact model before use.
Browse Perkins generators & specs →
Before you start
- Disconnect the batteries and any other power that can start the engine.
Procedure
- Remove the wing nut (A1) and remove the breather cover (A3). Check the seal around the cover, renew if necessary.
- Remove the filter elements (A2) from the breather body (A5).
- Wash the elements in a suitable fluid. Dry the elements and inspect them, renew if necessary.
- Fit the filter elements (A2) into the breather body (A5).
- Fit the cover (A3) and check that the cover is fitted onto the dowel (A4) correctly.
- Tighten the wing nut (A1) securely.
- Connect the power supply to the starter motor.
Source: manual:4006-23 series_TPCD1508-000-en.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.