Perkins — Copying Configuration Parameters
Operation · ECM
From a Perkins service manual — check it applies to your exact model before use.
Browse Perkins generators & specs →
Before you start
- Changing the parameters during engine operation can cause the engine to operate erratically and can cause engine damage. Only change the settings of the parameters when the engine is STOPPED.
Procedure
- Connect to the electronic service tool.
- Select the Service tab.
- Select the Configuration tab to view the configuration parameters.
- If an ECM is replaced, copy the parameters from the old ECM with the Copy Configuration feature of the electronic service tool. Alternatively, record the settings on paper and program them into the co
Tools required
- Electronic service tool Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.