Home›Repair guides›Perkins›Connecting the Electronic Service Tool and the CA3 Kit

Perkins — Connecting the Electronic Service Tool and the CA3 Kit

Testing & diagnosis

From a Perkins service manual — check it applies to your exact model before use.

Browse Perkins generators & specs →

Procedure

  1. Turn the keyswitch to the OFF position.
  2. Connect cable (2) between the COMPUTER end of CA3 adapter (3) and a USB port of PC (1).
  3. Connect cable (4) between the DATA LINK end of CA3 adapter (3) and the service tool connector.
  4. Place the keyswitch in the ON position. If the Electronic Service Tool and the CA3 adapter do not communicate with the ECM, refer to Troubleshooting, Electronic Service Tool Does Not Communicate.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.