From a Perkins service manual — check it applies to your exact model before use.
Browse Perkins generators & specs →
Procedure
- Loosen the hose clamp and disconnect hose (2).
- Remove fasteners (1) and remove air cleaner (3) from mounting bracket (4). Note orientation.
- If necessary, remove the bolts that secure mounting bracket (4) and remove it.
- Position mounting bracket (4) on the cylinder head and install bolts. Tighten M12 bolts to 100 N·m (74 lb ft); tighten 3/8" bolts to 47 N·m (35 lb ft).
- Position air cleaner (3) on mounting bracket (4) with correct orientation.
- Install fasteners (1). Tighten to 55 N·m (41 lb ft).
- Connect hose (2) and tighten the hose clamp securely.
Specs & values
- 100 N·m (74 lb ft) M12 bolts
- 47 N·m (35 lb ft) 3/8" bolts
- 55 N·m (41 lb ft) fasteners (1)
Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.