Home›Repair guides›Perkins›To test the fuel lift pump

Perkins 900 Series — To test the fuel lift pump

Testing & diagnosis · Fuel system

For the Perkins 900 Series, from the Perkins service manual.

Applies to: Perkins 900 Series CP/CR engine

Procedure

  1. Disconnect fuel outlet pipe; fit 0-70 kPa pressure gauge to outlet.
  2. Release connection at gauge and operate priming lever to eliminate air.
  3. Operate starter motor for 10 seconds with stop control in stop position.
  4. Note maximum pressure. If less than 42/70 kPa, repair or renew pump.
  5. Check rate pressure reduces to half maximum; if less than 30 seconds, repair or renew pump.
  6. Remove gauge and connect outlet pipe.
  7. Release vent screw on filter head and operate priming lever until fuel free of air; tighten.
  8. Connect engine stop solenoid.

Tools required

  • 0-70 kPa (0-10 lbf/in2) pressure gauge Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Test pressure 42/70 kPa (6/10 lbf/in2) 0,4/0,7 kgf/cm2
  • Pressure reduction to half maximum in at least 30 seconds

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.