Home›Repair guides›Perkins›To fill and vent the cooling system

Perkins 900 Series — To fill and vent the cooling system

Maintenance

For the Perkins 900 Series, from the Perkins service manual.

Applies to: Perkins 900 Series CP/CR engine

Before you start

  • Do not remove filler cap while engine hot and system under pressure.

Procedure

  1. Remove filler cap carefully.
  2. Fill cooling system until coolant reaches bottom of filler tube.
  3. If vent screw fitted in cylinder head, loosen it.
  4. When coolant free from air flows from vent point, tighten vent screw.
  5. If brass thermostat fitted horizontally, loosen vent screw on top until just tight.
  6. When coolant free from air flows, tighten thermostat vent screw.
  7. Remove filler cap and add coolant to bottom of filler tube; fit cap.
  8. Start engine, operate at 1750 rev/min for two minutes, stop and allow to cool.
  9. Repeat venting and filling until all air is eliminated.

Specs & values

  • Engine run at 1750 rev/min for two minutes

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →