Perkins 900 Series — To check and to adjust valve tip clearances
Adjustments · Valve train
For the Perkins 900 Series, from the Perkins service manual.
Applies to: Perkins 900 Series CP/CR engine
Procedure
- Check clearance with feeler gauges between top of valve stem and rocker lever, engine hot or cold.
- Rotate crankshaft until inlet valve of number 1 cylinder has just opened and exhaust valve has not closed completely.
- Check/adjust clearance of valve number 3 and number 6.
- Set valves of number 2 cylinder as above, check/adjust valve number 2 and number 5.
- Set valves of number 3 cylinder, check/adjust valve number 1 and number 4.
- Fit rocker cover and tighten cap nuts to 30 Nm metal cover or 20 Nm plastic cover.
Tools required
- Feeler gauges Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Inlet 0,20 mm (0.008 in)
- Exhaust 0,45 mm (0.018 in)
Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.