Home›Repair guides›Perkins›Water Temperature Regulator - Test

Perkins 403F-11 — Water Temperature Regulator - Test

Testing & diagnosis

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Before you start

  • Personal injury can result from escaping fluid under pressure.

Procedure

  1. Remove water temperature regulator from engine.
  2. Heat water in pan to fully open temperature of regulator and stir.
  3. Hang regulator below surface and away from sides and bottom of pan.
  4. Keep water at correct temperature for 10 minutes.
  5. Remove and immediately measure opening; replace if less than specified.

Specs & values

  • 10 minutes

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.