Perkins 403F-11 — Glow Plugs - Test
Testing & diagnosis
For the Perkins 403F-11, from the Perkins service manual.
Applies to: Perkins 403F-11
Procedure
- Connect test light between ground and glow plug terminal farthest from battery; turn starting aid switch ON.
- Loosen nut and disconnect connectors from glow plugs.
- Measure resistance between glow plug terminal and ground.
- Connect test light to battery positive and glow plug terminal; replace glow plug if light does not turn on.
- Install connector on each glow plug and tighten nut.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- 1.0 ohm maximum for 402F-05 FridayParts $19.90 and 403F-07 FridayParts $34.75
- 0.0139 ohm maximum for 403F-11 FridayParts $22.00 and 403F-15 FridayParts $19.35 SinoCMP $339.00
Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.