Home›Repair guides›Perkins›Fuel System - Prime

Perkins 403F-11 — Fuel System - Prime

Maintenance

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Before you start

  • Contain and dispose of all fluids according to local regulations.

Procedure

  1. For electric priming pump, turn keyswitch ON for 2 minutes, then OFF, then ON again.
  2. For mechanical priming, ensure air removed from primary filter before priming.
  3. Loosen vent screws on primary filter until fuel free from air flows, then close.
  4. Open vent screw on fuel filter and operate priming pump; do not operate starting motor more than 15 seconds, wait 30 seconds before re-operating.
  5. When fuel free from air flows, tighten vent screw to 7 N·m (62 lb in).

Specs & values

  • 7 N·m (62 lb in)

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.