Home›Repair guides›Perkins›Fuel Shutoff Solenoid - Test

Perkins 403F-11 — Fuel Shutoff Solenoid - Test

Testing & diagnosis

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Procedure

  1. Remove fuel shutoff solenoid from engine.
  2. Use a 12 volt battery; connect positive terminal to one pin and negative to remaining pin.
  3. Verify plunger extends maximum distance; replace if it does not move.
  4. Use digital multimeter in series to measure current; should be 1.0 ± 0.1 amperes.
  5. Replace solenoid if current is not within tolerance and install on engine.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 1.0 ± 0.1 amperes

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.