Home›Repair guides›Perkins›Engine Valve Lash - Inspect/Adjust

Perkins 403F-11 — Engine Valve Lash - Inspect/Adjust

Adjustments · valve mechanism

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Before you start

  • Do not use the starter to turn the flywheel.
  • Hot engine components can cause burns; allow engine to cool.
  • Turn ignition switch OFF and disconnect stop solenoid connection to prevent accidental starting.

Procedure

  1. Remove valve mechanism cover with front housing installed.
  2. Rotate crankshaft clockwise viewed from front; when inlet valve of one cylinder starts to open and exhaust valve not fully closed, check the paired valves.
  3. Loosen valve adjustment screw locknut on adjustment screw.
  4. Place feeler gauge between rocker arm and valve; turn adjustment screw to achieve specification.
  5. Tighten locknut while holding adjustment screw from turning.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Inlet valve 0.2 ± 0.05 mm
  • Exhaust valve 0.2 ± 0.05 mm

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.