Perkins 403F-11 — Electric Starting System - Test

Testing & diagnosis

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Procedure

  1. Use multimeter in DC volts range to find starting system components that do not function.
  2. Move start control switch to activate starter solenoid.
  3. If solenoid does not operate, check battery cable terminal to ground for voltage.
  4. Connect lead to solenoid terminal fastened to starter motor and activate solenoid; voltage indicates problem in starter motor.
  5. Check the small wire terminal at solenoid and the start switch terminal for voltage or zero readings.