Home›Repair guides›Perkins›Coolant Temperature Switch - Test (Coolant Temperature Sensor)

Perkins 403F-11 — Coolant Temperature Switch - Test (Coolant Temperature Sensor)

Testing & diagnosis

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Procedure

  1. Use digital multimeter to measure resistance of the sensor.
  2. When coolant is 30°C or less, disconnect wire connector and measure resistance; should be approximately 1660 Ohms.
  3. Repeat at approximately 70°C; resistance should be approximately 428 Ohms.
  4. Replace sensor if resistance is not within given values.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • approximately 1660 Ohms at 30°C
  • approximately 428 Ohms at 70°C

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.