Home›Repair guides›Perkins›Air in Fuel - Test

Perkins 403F-11 — Air in Fuel - Test

Testing & diagnosis · fuel system

For the Perkins 403F-11, from the Perkins service manual.

Applies to: Perkins 403F-11

Before you start

  • Work carefully around a running engine.
  • Wear eye and face protection when using pressurized air.

Procedure

  1. Examine fuel system for leaks and check fuel level.
  2. Install fuel flow tube with sight gauge in return line; observe flow during cranking.
  3. If excessive air seen, install second sight gauge at inlet to fuel priming pump.
  4. Pressurize fuel tank to 35 kPa (5 psi), not exceeding 55 kPa (8 psi), and check for leaks.
  5. If source not found, connect external fuel supply to inlet of priming pump.

Tools required

  • fuel flow tube with visual sight gauge Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 35 kPa (5 psi)
  • 55 kPa (8 psi) maximum

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →