Perkins 1506 — Removal from Storage
Maintenance · Engine
For the Perkins 1506, from the Perkins owner's manual.
Applies to: Perkins 1506A engine, Perkins 1506C engine, Perkins 1506D engine
Procedure
- Remove all covers from engine and air cleaner; check the condition of the air filter element.
- Check the coolant pump belt and fan drive belts, then tension both belts.
- Check the coolant level.
- Remove valve cover, lubricate the valve train, install valve cover.
- Replace the fuel filters and prime the fuel system.
- Use a bar or turning tool to turn the engine in the normal direction of rotation.
- If stored more than 1 year, pre-lubricate with engine oil at minimum 0.25 bar (3.6 psi) for 15 seconds.
- Check engine oil level and visually inspect all hoses and connections before starting the engine.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Prelube pressure 0.25 bar (3.6 psi) for 15 seconds
- Prelube connection 9/16" x 18 tpi
- Plug torque 30 N·m (265 lb in)
- Minimum ambient temperature 10 °C (50 °F)
Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.