Perkins 1506 — Coolant (ELC) - Change
Maintenance · Cooling system
For the Perkins 1506, from the Perkins owner's manual.
Applies to: Perkins 1506A engine, Perkins 1506C engine, Perkins 1506D engine
Before you start
- Pressurized System: Hot coolant can cause serious burns.
Procedure
- Stop the engine and allow to cool; loosen filler cap slowly to relieve pressure and remove.
- Remove drain plug (1) and the radiator drain plug; allow coolant to drain.
- Flush cooling system with clean water to remove debris.
- Fill with clean water, install filler cap, run engine until normal operating temperature.
- Stop engine, cool, remove cap and drain plugs; drain water and flush with clean water.
- Check O ring seal on drain plug, replace if damaged; install drain plugs and tighten drain plug (1) to 80 N·m (59 lb ft).
- Fill with Extended Life Coolant (ELC); do not install filler cap.
- Run engine until normal operating temperature; stop engine.
- Maintain coolant level at maximum mark.
- Clean and inspect filler cap gasket; replace or pressure test cap as needed.
- Start engine and inspect cooling system for leaks and proper operating temperature.
Specs & values
- Drain plug torque 80 N·m (59 lb ft)
- Do not fill the cooling system faster than 5 L (1.3 US gal) per minute
Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.