Perkins 1506 — Battery - Replace
Maintenance
For the Perkins 1506, from the Perkins owner's manual.
Applies to: Perkins 1506A engine, Perkins 1506C engine, Perkins 1506D engine
Before you start
- Batteries give off combustible gases which can explode.
- The battery cover should be removed before any servicing is attempted.
Procedure
- Switch the engine to OFF and remove all electrical loads; allow 2 minutes for diesel exhaust fluid lines to purge before disconnecting power.
- Turn off and disconnect any battery chargers.
- Ensure the battery disconnect switch is in the OFF position.
- Disconnect the NEGATIVE "-" cable from the NEGATIVE "-" battery terminal.
- Disconnect the POSITIVE "+" cable from the POSITIVE "+" battery terminal.
- Remove the used battery and install the new battery.
- Connect the POSITIVE "+" cable to the POSITIVE "+" terminal.
- Connect the NEGATIVE "-" cable to the NEGATIVE "-" terminal.
- Turn the battery disconnect switch to ON.
Specs & values
- After the engine has stopped, allow 2 minutes for diesel exhaust fluid lines to purge
Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.