Home›Repair guides›Perkins›Battery or Battery Cable - Disconnect

Perkins 1506 — Battery or Battery Cable - Disconnect

Maintenance

For the Perkins 1506, from the Perkins owner's manual.

Applies to: Perkins 1506A engine, Perkins 1506C engine, Perkins 1506D engine

Before you start

  • Removing the battery cables or the batteries with the cover in place may cause a battery explosion resulting in personal injury.

Procedure

  1. Turn the start switch to OFF; turn the ignition switch (if equipped) to OFF and remove the key and all electrical loads.
  2. Disconnect the negative battery terminal; ensure the cable cannot contact the terminal (with four 12 volt batteries, two negative connections must be disconnected).
  3. Remove the positive connection.
  4. Clean all disconnected connection and battery terminals.
  5. Use fine grade sandpaper to clean the terminals and cable clamps until bright or shiny; coat with silicone lubricant or petroleum jelly.
  6. Tape the cable connections to help prevent accidental starting.
  7. Proceed with necessary system repairs.
  8. To connect the battery, connect the positive connection before the negative connector.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →