Procedure

  1. Remove water temperature regulator from engine.
  2. Heat water in pan to fully open temperature of regulator.
  3. Hang regulator in pan, below surface, away from sides and bottom.
  4. Keep water at correct temperature for ten minutes.
  5. Remove regulator; immediately measure opening.
  6. Replace if distance less than specification.

Full service-parts list: Perkins 1106 →