Home›Repair guides›Perkins›To Change to Perkins ELC

Perkins 1106 — To Change to Perkins ELC

Maintenance · Cooling system

For the Perkins 1106, from the Perkins owner's manual.

Applies to: Perkins 1106

Before you start

  • Incorrect or incomplete flushing of the cooling system can result in damage to copper and other metal components.

Procedure

  1. Drain the coolant into a suitable container.
  2. Dispose of the coolant according to local regulations.
  3. Flush the system with clean water to remove debris.
  4. Use Perkins cleaner to clean the system following the label instructions.
  5. Drain the cleaner and flush the cooling system with clean water.
  6. Fill with clean water and operate the engine until warmed to 49 to 66 C (120 to 150 F).
  7. Drain the cooling system and flush with clean water.
  8. Repeat steps 6 and 7 until the system is completely clean.
  9. Fill the cooling system with Perkins Premixed ELC.

Full service-parts list: Perkins 1106 →

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.