Home›Repair guides›Perkins›Testing The Radiator And Cooling System For Leaks

Perkins 1106 — Testing The Radiator And Cooling System For Leaks

Testing & diagnosis

For the Perkins 1106, from the Perkins service manual.

Applies to: Perkins 1106

Before you start

  • Personal injury can result from hot coolant, steam and alkali.

Procedure

  1. Loosen filler cap to first stop; release pressure; remove cap.
  2. Ensure coolant covers top of radiator core.
  3. Put pressurizing pump onto radiator.
  4. Increase pressure to 20 kPa (3 psi) more than filler cap operating pressure.
  5. Check radiator for leakage on outside.
  6. Check all connections and hoses for leaks.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Perkins 1106 →

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.