Perkins 1106 — Speed Demand Input Setup
Adjustments · ECM / Speed Demand Input
For the Perkins 1106, from the Perkins service manual.
Applies to: Perkins 1106, Perkins 1106D engine
Procedure
- From the menu select Services.
- On the Services screen select Throttle Configuration.
- Select the type of input: Analog throttle, PWM throttle, or Communications port throttle (J1939 TSC1).
- If analog input is selected, program the analog parameters into the ECM.
Tools required
- Electronic Service Tool Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Lower Diagnostic Limit default 5
- Lower Position Limit default 10
- Initial Lower Position default 20
- Lower Dead Zone % default 5
- Upper Dead Zone % default 5
- Initial Upper Position default 70
- Upper Position Limit default 85
- Upper Diagnostic Limit default 90
Full service-parts list: Perkins 1106 →, Perkins 1106D engine →
Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.