Home›Repair guides›Perkins›Fuel System - Prime (Hand Fuel Priming Pump)

Perkins 1106 — Fuel System - Prime (Hand Fuel Priming Pump)

Maintenance

For the Perkins 1106, from the Perkins owner's manual.

Applies to: Perkins 1106

Before you start

  • Do not loosen the high pressure fuel line in order to purge air from the fuel system.

Procedure

  1. Ensure the fuel system is in working order and the fuel supply valve is in the ON position.
  2. Operate the fuel priming pump; after 100 depressions of the pump, stop.
  3. The engine fuel system should now be primed and able to start.
  4. Operate the engine starter and crank the engine; run at low idle for a minimum of five minutes.

Specs & values

  • Do not crank the engine continuously for more than 30 seconds

Full service-parts list: Perkins 1106 →

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →